Our Mission Statement
NOJA Power provide high quality, quality assured medium voltage recloser related products and services to an international market. Use the links below to explore our available products.
News 2011
2011 March NOJA Power Commissioned to Supply Switchboard For Airport Link Project
News 2010
2010 December NOJA POWER Expands its Type Testing Capabilities
2010 November NOJA POWER Environmental Management System ISO14001 Certified
2010 July NOJA Power elevated to National Master Electrician Status
2010 June NOJA Power OSM38 KEMA Type Testing Completed
2010 March NOJA Power Motor Control Centres Empowers Queensland Coal Export
2010 March NOJA Power Auto Recloser Perfect Solution for Sectionalising
2010 March NOJA Power Low Voltage Motor Control Centres, Specify for Safety, Reliability and Performance
2010 June NOJA POWER OSM38 KEMA Type Testing Completed
2010 Febuary TELUS and OSM Recloser Provide Smart Grid Solution
2010 January NOJA Power Auto Recloser Operating Smart Grids Below Freezing
News 2009
2009 October NOJA Power Winner of the 2009 Premier of Queensland's Exporter of the Year Award
2009 August Trade Queensland International Business Cadetship Successfully Completed
2009 August Kanban & Lean Manufacturing Improve Productivity
2009 August NOJA Power OSM27 Type Tested at KEMA
2009 August NOJA Power New Corporate Office and Factory
2009 Feburary NOJA Power Reclosers to Increase Distribution Network Reliability in Brazil
2009 Feburary Powerco Successfully Commissions Automatic Backfeed Restoration Scheme
2009 Feburary NOJA Power Continues to Supply MCCs for Abbot Point Coal Export Upgrade
News 2008
2008 November ENERGEX Awards NOJA Power a Recloser Supply Contract as Part of Network Upgrade Program
2008 September Factory Expansion Increases Production Capabilities
2008 August Practical Perspective on Recloser Training
2008 August NOJA Powers Brisbane Clem Jones Tunnel
2008 June NOJA Power Commended on Manufacturing Endeavours
2008 June OSM Reclosers helps Mine through Bat Season
2008 May NOJA Power exhibits OSM Recloser reliability at IEEE Conference
2008 April NOJA Power Awarded for Exporting Success
2008 April Brazilian Intern Graduates & Joins NOJA Power Distributor
2008 March NOJA Power Teams up to Supply PNG Power
2008 March Solid-Dielectric ACR Installation Improves Distribution Network Reliability
2008 Feburary NOJA Power to Exhibit at Upcoming IEEE PES Conference & Exhibition
News 2007
2007 October NOJA Power Switchgear Pty Ltd Appoints Exclusive Distributor for the Territory of New Zealand
2007 September Fiji Electricity Authority Contract Award
2007 September ENERGEX Reaps Benefits of OSM Installations
2007 August Planning for the future: Water Matters
2007 August ETSA Utilities Award 5 Year Supply Contract
2007 August NOJA Power & Comulsa exhibit at Exponor Conference, Chile
2007 January Gold Coast Airport upgrades using OSM Recloser
News 2006
2006 November NOJA Power receives AEEMA Excellence in Exporting Award 2006
2006 November Trinidad & Tobago Electricity take delivery of NOJA Power OSM Reclosers
2006 September NOJA Power welcomes new member to sales team
2006 August Fiji Electricity Authority Remote Controls NOJA Power Reclosers
2006 July New Shipment to Bangladesh
2006 June A Global Bank to Support A Global Business
2006 June Motor control centres come as standard
2006 June Standard design for motor control centres improves quality
2006 August Fiji Electricity Authority Remote Controls NOJA Power Reclosers
2006 May Think Motor Control Centres - Think NOJA Power
2006 May 132kV Substation Protection and SCADA control project
2006 May Reliable power thanks To NOJA Power reclosers
2006 May Live line work: Is your switchgear fault contained?
ENERGEX Reaps Benefits of OSM Installations
ENERGEX supplies approximately 1.3 million customers in South East Queensland covering an area of 25,000 square km and are constantly looking for means of increasing network performance.
Commencing in 2003/04 financial year ENERGEX installed approximately 50 NOJA Power OSM automatic circuit reclosers (ACR's) on predominantly its urban network. In the majority of cases a single recloser was placed at the half-way point along the backbone or main trunk of the feeder. In a small number of cases, the ACR was placed on one or both feeder legs at the substation of double cable box feeders.
This program represented a relatively small number of feeders out of a total population of around 1000 urban feeders. The majority (70%) of the 50 ACRS were installed and commissioned by 31 Jan 2004, with the rest installed in 2004/05 and 2005/06.
This group of feeders supplies around 65,000 customers and has a total installed circuit exposure of 290 urban km and 460 rural km. This equates to approximately 5% of ENERGEX's total customer base and around 4.5% of the circuit length of the urban network and around 3% of the rural network.
For the period since commissioning to December 2006, there have been 101 faults beyond the reclosers due to all causes (non-storm and storm events).

Energex installation crew on site
16 of these events occurred during severe weather for which a major event day (MED) exclusion was granted. 32 out of the 50 feeders with the installed ACR had an outage during this period. Out of the 32 feeders, half of the feeders accounted for around 75% of the faults.
The estimated SAIDI saving for the period is 4.8 minutes excluding MEDs.
The total SAIDI saving with all events included is 11.4 minutes. This saving is estimated by theoretically calculating the impact of the fault with and without the ACR installed.
Following the initial 50 NOJA Power OSM's a further 70 ACR's were purchased and installed.