Our Mission Statement
NOJA Power provide high quality, quality assured medium voltage recloser related products and services to an international market. Use the links below to explore our available products.
News 2011
2011 March NOJA Power Commissioned to Supply Switchboard For Airport Link Project
News 2010
2010 December NOJA POWER Expands its Type Testing Capabilities
2010 November NOJA POWER Environmental Management System ISO14001 Certified
2010 July NOJA Power elevated to National Master Electrician Status
2010 June NOJA Power OSM38 KEMA Type Testing Completed
2010 March NOJA Power Motor Control Centres Empowers Queensland Coal Export
2010 March NOJA Power Auto Recloser Perfect Solution for Sectionalising
2010 March NOJA Power Low Voltage Motor Control Centres, Specify for Safety, Reliability and Performance
2010 June NOJA POWER OSM38 KEMA Type Testing Completed
2010 Febuary TELUS and OSM Recloser Provide Smart Grid Solution
2010 January NOJA Power Auto Recloser Operating Smart Grids Below Freezing
News 2009
2009 October NOJA Power Winner of the 2009 Premier of Queensland's Exporter of the Year Award
2009 August Trade Queensland International Business Cadetship Successfully Completed
2009 August Kanban & Lean Manufacturing Improve Productivity
2009 August NOJA Power OSM27 Type Tested at KEMA
2009 August NOJA Power New Corporate Office and Factory
2009 Feburary NOJA Power Reclosers to Increase Distribution Network Reliability in Brazil
2009 Feburary Powerco Successfully Commissions Automatic Backfeed Restoration Scheme
2009 Feburary NOJA Power Continues to Supply MCCs for Abbot Point Coal Export Upgrade
News 2008
2008 November ENERGEX Awards NOJA Power a Recloser Supply Contract as Part of Network Upgrade Program
2008 September Factory Expansion Increases Production Capabilities
2008 August Practical Perspective on Recloser Training
2008 August NOJA Powers Brisbane Clem Jones Tunnel
2008 June NOJA Power Commended on Manufacturing Endeavours
2008 June OSM Reclosers helps Mine through Bat Season
2008 May NOJA Power exhibits OSM Recloser reliability at IEEE Conference
2008 April NOJA Power Awarded for Exporting Success
2008 April Brazilian Intern Graduates & Joins NOJA Power Distributor
2008 March NOJA Power Teams up to Supply PNG Power
2008 March Solid-Dielectric ACR Installation Improves Distribution Network Reliability
2008 Feburary NOJA Power to Exhibit at Upcoming IEEE PES Conference & Exhibition
News 2007
2007 October NOJA Power Switchgear Pty Ltd Appoints Exclusive Distributor for the Territory of New Zealand
2007 September Fiji Electricity Authority Contract Award
2007 September ENERGEX Reaps Benefits of OSM Installations
2007 August Planning for the future: Water Matters
2007 August ETSA Utilities Award 5 Year Supply Contract
2007 August NOJA Power & Comulsa exhibit at Exponor Conference, Chile
2007 January Gold Coast Airport upgrades using OSM Recloser
News 2006
2006 November NOJA Power receives AEEMA Excellence in Exporting Award 2006
2006 November Trinidad & Tobago Electricity take delivery of NOJA Power OSM Reclosers
2006 September NOJA Power welcomes new member to sales team
2006 August Fiji Electricity Authority Remote Controls NOJA Power Reclosers
2006 July New Shipment to Bangladesh
2006 June A Global Bank to Support A Global Business
2006 June Motor control centres come as standard
2006 June Standard design for motor control centres improves quality
2006 August Fiji Electricity Authority Remote Controls NOJA Power Reclosers
2006 May Think Motor Control Centres - Think NOJA Power
2006 May 132kV Substation Protection and SCADA control project
2006 May Reliable power thanks To NOJA Power reclosers
2006 May Live line work: Is your switchgear fault contained?
OSM Recloser Interface Test Set
The implementation of testing procedures is an integral aspect of both the switchgear manufacturing and servicing processes. Possessing the ability to conduct testing both in house and on the field ensures the safety, lifespan and rated operation of switchgear devices.
Due to the large range of primary fault currents (up to 16000A), relays are generally tested using secondary injection, whereby the relays are subjected to the same currents they would normally receive from the secondary of a CT. However, unlike general protection relays, the OSM recloser does not provide discrete inputs for CT connections, making it difficult to introduce a secondary signal to the MPM. Furthermore, the recloser utilises Rogowski sensors within the cubicle instead of CT's, which output a voltage signal proportional to the input current. This does not allow for a current signal to be injected into the MPM.
![]() NOJA Power Interface Test Set |
To overcome this problem, NOJA Power provides an Test Set to simulate the current and voltage signals generated by sensors inside the OSM15 and OSM27 recloser bushing.
The Interface Test Set uses Rogowski transformers to convert an injected current signal into the voltage signal that the MPM is expecting. When used in conjunction with a power system and three phase test set it can be used to conduct the following tests:
- Three phase short circuit
- Phase to phase short circuit
- Earth fault
- Upstream broken wire
- Low source voltage
- Loss of supply
In addition to this functionality, this device has external voltage free contacts both normally open and normally closed that simulate the positioning of the contacts. The simulator also allows coil faults to be actioned and include; Mechanical Trip / Manual Trip, Simulator Coil Short Circuit, Simulator Coil Open Circuit.
The Interface Test Set allows for either the OSM or Simulator to be selected for coil operation from the MPM. This offers several advantages during application. As the MPM provides directional protection using voltage as a reference to determine current directions, the Interface Test Set provides an interface so that LV can be applied that the MPM will interpret as MV to allow for directional testing. This also provides the means to test UV1, Uv2 and UV3 based protection.